HC9D2 versions: 5 different intensification factors
PIN: 20 – 207 bar
PH: 1,380 bar maximum
PRETURN: As low as possible (return pressure to tank)
POUTLET: PH = (PIN – PRETURN) I (intensification)
The intensification ratio is related to the inlet pressure on media 2, the values in the table are measured at 1 bar on media 2.
Drain connections: Max. 10 bar
Mounting: Inline tube
Weight: 25.0 kg.
Model version:
A model = no dump valve
Material certificate 3.1 on request
Providing further details on product specifications and dimensions
Get a quoteHydrastore use cookies to make the site run smoothly, enhance the content and to gather information on how you use it in order to improve and personalise your experience. See our Privacy Policy