HC9D2W versions: 5 different intensification factors
PIN: 20 – 207 bar
PH: 1,380 bar maximum
PRETURN: As low as possible (return pressure to tank)
POUTLET: PH = (PIN – PRETURN) I (intensification)
The intensification ratio is related to the inlet pressure on media 2, the values in the table are measured at 1 bar on media 2.
Drain connections: Max. 10 bar
Mounting: Inline tube
Weight: 25.0 kg.
Model version:
A model = no dump valve
Material certificate 3.1 on request
Providing further details on product specifications and dimensions