When designing hydraulic systems, it is important to use correctly sized equipment that is appropriate for the application. Not only does this ensure the equipment is fit for purpose it will also prove cost effective.
Correctly applied calculations lay the foundations to an efficient and cost effective system. We have provided design engineers with a compact document that contains formulae required to calculate:
By following the calculations laid out in this article, or using the online hydraulic calculators embedded within the Hydrastore website, you will quickly and accurately calculate each discrete parameter for your hydraulic system.
The basic equation of force is:
F (Force) = P (Pressure) x A (Surface Area).
Determining the correct sized electric motor for your hydraulic system will aid in reducing energy consumption while increasing efficiency. Ensuring the motor is operating at peak continuous load is key, but knowing the exact power requirement is very important.
Qα √ Δρ
i.e. if the flow is doubled the pressure drop increases in the ratio 4:1
Where:
Q = Flow Rate [L/min]
n = Shaft Speed [rev/min]
p = Pressure [bar]
P = Power [kW]
D = Displacement [cm³/rev]
F = Force [N]
v = Velocity [m/s]
T = Torque [Nm]
A = Area [cm²]
d = Pipe Diameter [mm]
Δρ = Pressure Drop (bar)
Useful Conversions
1 Litre = 1000 cm³
1 bar = 100000 Pa
1 bar = 14.5 psi
Note: component efficiencies need to be considered for a more precise analysis.
Where:
d = Pipe Diameter (mm)
Based on oils having a maximum viscosity grade of 70 cSt at 38°C and operating between 18°C and 51°C.
Note: For pipe runs greater than 10m the pipe size should be increased correspondingly. The intake line should never exceed 1m in length.
Flushing is a process designed to remove dirt introduced into the system during manufacture, assembly and initial operation. It is also used when significant maintenance is undertaken. The requirements are summarised below:-
Where:
Q = Flow Rate (I/min)
v = Viscosity (cSt)
d = Pipe Diameter (mm)
Re = Reynolds Number
A ‘fine’ filter to capture transported particles quickly and effectively.
V=Voltage (volts)
I=Current (amps)
R=Resistance (ohms)
P=Power (watts)
Pascal’s Law, or Pascal’s Principle as it is also known, was first established by French mathematician Blaise Pascal and published in 1663. It is a law that states, in fluid mechanics, pressure in one part of a closed container with fluid at rest transmits to every portion of the fluid and to the walls of the container, without loss.
Pressure is equal to the force divided by the area on which it acts. In a hydraulic system, the pressure exerted on a piston produces an equal increase in pressure on another piston in the system. The force on the second piston is 10 times greater if the area of the second piston is also 10 times that of the first. However, the pressure is the same as that on the first piston.
The hydraulic press is a perfect example of Pascal’s Principle in action and is also applied in the use of hydraulic brakes.
Hydraulic pumps are designed to produce a flow of fluid through the system. Pressure in the system occurs as a result of any resistance to the flow of the fluid. According to Pascal’s Law, cylinders within the system will all move at their own rate based on the weight of the load being moved. A calculation is needed to understand how far each cylinder will extend.
Posted by admin in category Hydraulic Systems Advice on Friday, 10th March 2023
Call our knowledgeable team Mon–Fri 8:30am–5pm
Systems & Components Division 01427 874445
sales@hydrastore.co.uk
Hose Division 0121 326 6395
hoses@hydrastore.co.uk
Hydrastore use cookies to make the site run smoothly, enhance the content and to gather information on how you use it in order to improve and personalise your experience. See our Privacy Policy