MiniBooster HC6D2

HC6D2 versions: 9 different intensification factors

PIN: 20 – 207 bar

PH: 800 bar maximum

PRETURN: As low as possible (return pressure to tank)

POUTLET: PH = (PIN – PRETURN) x intensification factor

The intensification ratio is related to the inlet pressure on media 2, the values in the table are measured at 1 bar on media 2.

Drain connections: Max. 10 bar

Mounting: Inline tube

Weight: 24.0 kg.

Model version:

A model = no dump valve

Material certificate 3.1 on request

Get a custom quote